Oil Rig & Top Drive Cable
Offshore platform and top drive cable up to 2000 V — tinned copper, EPR or LSHF, braided screen, 125 °C conductor, oil and corrosion resistant.
LV and MV shipboard power, lighting and control cable to IEC 60092 — XLPE or EPR insulation, up to 26/35 kV, with flame-retardant, fire-resistant and LSZH options.
| Application | Fixed installation in power, lighting and control circuits on ships and offshore platforms |
|---|---|
| Standards | IEC 60092-350, -353, -354, -360; IEC 60228 |
| Voltage classes | 0.6/1 kV (LV); 3.6/6 to 18/30 kV (MV); 26/35 kV on request |
| Insulation | XLPE or EPR; semi-conducting screens on MV |
| Conductor | Bare or tinned stranded copper, class 2 or class 5 |
| Armour / sheath | Tinned copper braid; SHF1, SHF2, PVC or CR inner sheath |
| Temperature | 90 °C continuous; 250 °C short circuit (5 s) |
| Bending radius | 12 × OD single core; 9 × OD three core |
| 3.6/6 kV | 10 – 300 mm² single core · 10 – 240 mm² three core |
| 6/10 kV | 16 – 300 mm² · 16 – 240 mm² |
| 8.7/15 kV | 25 – 300 mm² · 25 – 240 mm² |
| 12/20 kV | 35 – 300 mm² · 35 – 240 mm² |
| 18/30 kV | 50 – 300 mm² · 50 – 240 mm² |
| On request | Flame retardant IEC 60332-1 / 60332-3-24; fire resistant IEC 60331 (mica tape); LSZH IEC 61034 + IEC 60754 |
Send the detailed requirement — vessel type and size, service conditions, voltage or medium, quantities, and the drawing or specification reference. The build-up, the approval route and the delivery terms are then recommended for that requirement and confirmed with the quotation.
Offshore platform and top drive cable up to 2000 V — tinned copper, EPR or LSHF, braided screen, 125 °C conductor, oil and corrosion resistant.
Reeling, festoon and towline cable for fast-moving port machinery — 0.6/1 kV to 12/20 kV, EPR, split earth cores, fibre-optic composite option.